Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
Neuromodulation ; 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38483366

ABSTRACT

BACKGROUND: Adults with refractory, mechanical chronic low back pain associated with impaired neuromuscular control of the lumbar multifidus muscle have few treatment options that provide long-term clinical benefit. This study hypothesized that restorative neurostimulation, a rehabilitative treatment that activates the lumbar multifidus muscles to overcome underlying dysfunction, is safe and provides relevant and durable clinical benefit to patients with this specific etiology. MATERIALS AND METHODS: In this prospective five-year longitudinal follow-up of the ReActiv8-B pivotal trial, participants (N = 204) had activity-limiting, moderate-to-severe, refractory, mechanical chronic low back pain, a positive prone instability test result indicating impaired multifidus muscle control, and no indications for spine surgery. Low back pain intensity (10-cm visual analog scale [VAS]), disability (Oswestry Disability Index), and quality of life (EuroQol's "EQ-5D-5L" index) were compared with baseline and following the intent-to-treat principle, with a supporting mixed-effects model for repeated measures that accounted for missing data. RESULTS: At five years (n = 126), low back pain VAS had improved from 7.3 to 2.4 cm (-4.9; 95% CI, -5.3 to -4.5 cm; p < 0.0001), and 71.8% of participants had a reduction of ≥50%. The Oswestry Disability Index improved from 39.1 to 16.5 (-22.7; 95% CI, -25.4 to -20.8; p < 0.0001), and 61.1% of participants had reduction of ≥20 points. The EQ-5D-5L index improved from 0.585 to 0.807 (0.231; 95% CI, 0.195-0.267; p < 0.0001). Although the mixed-effects model attenuated completed-case results, conclusions and statistical significance were maintained. Of 52 subjects who were on opioids at baseline and had a five-year visit, 46% discontinued, and 23% decreased intake. The safety profile compared favorably with neurostimulator treatments for other types of back pain. No lead migrations were observed. CONCLUSION: Over a five-year period, restorative neurostimulation provided clinically substantial and durable benefits with a favorable safety profile in patients with refractory chronic low back pain associated with multifidus muscle dysfunction. CLINICAL TRIAL REGISTRATION: The Clinicaltrials.gov registration number for the study is NCT02577354; registration date: October 15, 2016; principal investigator: Christopher Gilligan, MD, Brigham and Women's Hospital, Boston, MA, USA. The study was conducted in Australia (Broadmeadow, New South Wales; Noosa Heads, Queensland; Welland, South Australia; Clayton, Victoria), Belgium (Sint-Niklaas; Wilrijk), The Netherlands (Rotterdam), UK (Leeds, London, Middlesbrough), and USA (La Jolla, CA; Santa Monica, CA; Aurora, CO; Carmel, IN; Indianapolis, IN; Kansas City, KS; Boston, MA; Royal Oak, MI; Durham, NC; Winston-Salem, NC; Cleveland, OH; Providence, RI; Spartanburg, SC; Spokane, WA; Charleston, WV).

2.
Neuromodulation ; 26(1): 87-97, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35088722

ABSTRACT

BACKGROUND: Impaired neuromuscular control and degeneration of the multifidus muscle have been linked to the development of refractory chronic low back pain (CLBP). An implantable restorative-neurostimulator system can override the underlying multifidus inhibition by eliciting episodic, isolated contractions. The ReActiv8-B randomized, active-sham-controlled trial provided effectiveness and safety evidence for this system, and all participants received therapeutic stimulation from four months onward. OBJECTIVE: This study aimed to evaluate the two-year effectiveness of this restorative neurostimulator in patients with disabling CLBP secondary to multifidus muscle dysfunction and no indications for spine surgery. MATERIALS AND METHODS: Open-label follow-up of 204 participants implanted with a restorative neurostimulation system (ReActiv8, Mainstay Medical, Dublin, Ireland) was performed. Pain intensity (visual analog scale [VAS]), disability (Oswestry disability index [ODI]), quality-of-life (EQ-5D-5L), and opioid intake were assessed at baseline, six months, one year, and two years after activation. RESULTS: At two years (n = 156), the proportion of participants with ≥50% CLBP relief was 71%, and 65% reported CLBP resolution (VAS ≤ 2.5 cm); 61% had a reduction in ODI of ≥20 points, 76% had improvements of ≥50% in VAS and/or ≥20 points in ODI, and 56% had these substantial improvements in both VAS and ODI. A total of 87% of participants had continued device use during the second year for a median of 43% of the maximum duration, and 60% (34 of 57) had voluntarily discontinued (39%) or reduced (21%) opioid intake. CONCLUSIONS: At two years, 76% of participants experienced substantial, clinically meaningful improvements in pain, disability, or both. These results provide evidence of long-term effectiveness and durability of restorative neurostimulation in patients with disabling CLBP, secondary to multifidus muscle dysfunction. CLINICAL TRIAL REGISTRATION: The study is registered on clinicaltrials.gov with identifier NCT02577354.


Subject(s)
Chronic Pain , Low Back Pain , Humans , Low Back Pain/etiology , Low Back Pain/therapy , Treatment Outcome , Paraspinal Muscles , Analgesics, Opioid , Pain Measurement , Chronic Pain/etiology , Chronic Pain/therapy
3.
Neuromodulation ; 26(1): 98-108, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36175320

ABSTRACT

BACKGROUND: Restorative neurostimulation is a rehabilitative treatment for patients with refractory chronic low back pain (CLBP) associated with dysfunction of the lumbar multifidus muscle resulting in impaired neuromuscular control. The ReActiv8-B randomized, sham-controlled trial provided evidence of the effectiveness and safety of an implanted, restorative neurostimulator. The two-year analysis previously published in this journal demonstrated accrual of clinical benefits and long-term durability. OBJECTIVE: Evaluation of three-year effectiveness and safety in patients with refractory, disabling CLBP secondary to multifidus muscle dysfunction and no indications for spine surgery. MATERIALS AND METHODS: Prospective, observational follow-up of the 204 implanted trial participants. Low back pain visual analog scale (VAS), Oswestry Disability Index (ODI), EuroQol quality of life survey, and opioid intake were assessed at baseline, six months, and one, two, and three years after activation. The mixed-effects model repeated measures approach was used to provide implicit imputations of missing data for continuous outcomes and multiple imputation for proportion estimates. RESULTS: Data were collected from 133 participants, and 16 patients missed their three-year follow-up because of coronavirus disease restrictions but remain available for future follow-up. A total of 62% of participants had a ≥ 70% VAS reduction, and 67% reported CLBP resolution (VAS ≤ 2.5cm); 63% had a reduction in ODI of ≥ 20 points; 83% had improvements of ≥ 50% in VAS and/or ≥ 20 points in ODI, and 56% had these substantial improvements in both VAS and ODI. A total of 71% (36/51) participants on opioids at baseline had voluntarily discontinued (49%) or reduced (22%) opioid intake. The attenuation of effectiveness in the imputed (N = 204) analyses was relatively small and did not affect the statistical significance and clinical relevance of these results. The safety profile remains favorable, and no lead migrations have been observed to date. CONCLUSION: At three years, 83% of participants experienced clinically substantial improvements in pain, disability, or both. The results confirm the long-term effectiveness, durability, and safety of restorative neurostimulation in patients with disabling CLBP associated with multifidus muscle dysfunction. CLINICAL TRIAL REGISTRATION: The Clinicaltrials.gov registration number for the study is NCT02577354.


Subject(s)
Chronic Pain , Low Back Pain , Humans , Analgesics, Opioid , Chronic Pain/therapy , Low Back Pain/therapy , Paraspinal Muscles , Prospective Studies , Quality of Life , Treatment Outcome , Follow-Up Studies
4.
Pain ; 162(10): 2486-2498, 2021 10 01.
Article in English | MEDLINE | ID: mdl-34534176

ABSTRACT

ABSTRACT: Chronic low back pain can be caused by impaired control and degeneration of the multifidus muscles and consequent functional instability of the lumbar spine. Available treatment options have limited effectiveness and prognosis is unfavorable. We conducted an international randomized, double-blind, sham-controlled trial at 26 multidisciplinary centers to determine safety and efficacy of an implantable, restorative neurostimulator designed to restore multifidus neuromuscular control and facilitate relief of symptoms (clinicaltrials.gov identifier: NCT02577354). Two hundred four eligible participants with refractory mechanical (musculoskeletal) chronic LBP and a positive prone instability test indicating impaired multifidus control were implanted and randomized to therapeutic (N = 102) or low-level sham (N = 102) stimulation of the medial branch of the dorsal ramus nerve (multifidus nerve supply) for 30 minutes twice daily. The primary endpoint was the comparison of responder proportions (≥30% relief on the LBP visual analogue scale without analgesics increase) at 120 days. After the primary endpoint assessment, participants in the sham-control group switched to therapeutic stimulation and the combined cohort was assessed through 1 year for long-term outcomes and adverse events. The primary endpoint was inconclusive in terms of treatment superiority (57.1% vs 46.6%; difference: 10.4%; 95% confidence interval, -3.3% to 24.1%, P = 0.138). Prespecified secondary outcomes and analyses were consistent with a modest but clinically meaningful treatment benefit at 120 days. Improvements from baseline, which continued to accrue in all outcome measures after conclusion of the double-blind phase, were clinically important at 1 year. The incidence of serious procedure- or device-related adverse events (3.9%) compared favorably with other neuromodulation therapies for chronic pain.


Subject(s)
Chronic Pain , Low Back Pain , Chronic Pain/therapy , Double-Blind Method , Humans , Low Back Pain/therapy , Lumbosacral Region , Pain Measurement , Treatment Outcome
5.
Spine (Phila Pa 1976) ; 33(24): 2675-81, 2008 Nov 15.
Article in English | MEDLINE | ID: mdl-19011548

ABSTRACT

STUDY DESIGN: Experimental design using cadaveric computerized tomography (CT) scans and a computer-assisted image guidance system to compare various thoracic pedicle screw start points and trajectories. OBJECTIVE: To compare described thoracic pedicle screw start points and trajectories to determine which allows strictly intrapedicular screw placement with the most margin of error. SUMMARY OF BACKGROUND DATA: Thoracic pedicle screws are being used in a variety of spinal conditions to include fracture, tumor, and deformity. Optimal thoracic pedicle screw start points have received increasing attention in the literature. Optimal thoracic pedicle trajectory is still undetermined. METHODS: Using fine cut CT scans of 3 cadaveric male specimens (aged 65-70 years) loaded onto a computer-assisted image guidance system, 966 pedicle screws, were virtually inserted. The effective pedicle diameter (EPD) and maximum insertional arc (MIA) was assessed using 3 different trajectories and start points: (1) straight ahead, (2) straight forward, and (3) anatomic. EPD was measured by placing a maximum-sized virtual screw, using a specific trajectory, without cortical violation of the pedicle and/or the vertebral body. The MIA was assessed by measurement of the angle formed by the most superiorly and inferiorly directed 0.1-mm virtual screw through a given start point without violation of the pedicle cortex and obtaining at least 50% vertebral body purchase. RESULTS: Mean EPD in the sagittal plane was 7.6 +/- 0.3 (SEM) mm for the straight forward trajectory and 9.1 +/- 0.3 (SEM) mm for the anatomic trajectory, a 20% increase (P < 0.0005). Mean EPD in the axial plane was 4.1 +/- 0.2 (SEM) mm for the straight ahead trajectory and 5.0 +/- 0.2 (SEM) mm for the anatomic trajectory, a 22% increase (P < 0.0005). EPD was found to be statistically different based on the trajectory used for placement in both the axial and sagittal planes in the upper (T1-T4), middle (T5-T8), and lower (T9-T12) thoracic spine. Mean MIA in the sagittal plane was 18.7 +/- 1.1 (SEM) for straight ahead start points, 25.8 degrees +/- 0.8 degrees (SEM) for straight forward start points, and 30.2 degrees +/- 0.8 degrees (SEM) for anatomic start points, a 38% increase (P < 0.0005) in MIA compared with straight ahead and a 17% increase (P < 0.0005) in MIA compared with straight forward. Mean MIA in the axial plane was 17.8 degrees +/- 0.6 degrees (SEM) for straight ahead and anatomic start points, and 18.6 degrees +/- 0.6 degrees (SEM) for straight forward start points. This difference was not statistically significant (P = 0.086). MIA was found to be statistically different based on start points used in the sagittal, but not the axial plane, in the upper, middle, and lower thoracic spine. CONCLUSION: EPD and MIA are trajectory (EPD) and start point (MIA) dependent. In the axial plane, anatomic EPD was greater than straight ahead EPD. In the sagittal plane, anatomic EPD was greater than straight forward EPD. Using anatomic start points in the sagittal plane, a greater MIA is achievable. These data suggest that in the diminutive thoracic pedicle or when a larger screw is needed, an anatomic trajectory using anatomic start points may allow a larger bone channel for intrapedicular placement of instrumentation.


Subject(s)
Bone Screws , Orthopedic Procedures , Radiographic Image Interpretation, Computer-Assisted , Radiography, Interventional , Surgery, Computer-Assisted , Thoracic Vertebrae/surgery , Tomography, X-Ray Computed , Aged , Cadaver , Humans , Male , Orthopedic Procedures/instrumentation , Orthopedic Procedures/methods , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/methods , Thoracic Vertebrae/diagnostic imaging , User-Computer Interface
6.
Am J Orthop (Belle Mead NJ) ; 35(3): 144-6, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16610381

ABSTRACT

Iliac screw fixation is often used for long fusions to the sacropelvis. Maximum iliac screw purchase is obtained both by placing the screws within 1.5 cm of the greater sciatic notch and by extending them anterior to the axis of rotation in flexion-extension. Screw insertion is "blinded" or dependent on tactile feedback, and hence extreme care is necessary to avoid incorrect placement and damage to vital neurovascular structures in the pelvis and sciatic notch. Long screws may violate the hip joint while medial placement may injure the lumbosacral plexus and the nearby vessels. To explore the best intraoperative fluoroscopic method of determining optimal iliac screw placement, we used a synthetic pelvis model to investigate screw placement conditions: (1) optimal anatomic placement, (2) violation of the sciatic notch, (3) hip joint violation, (4) medial wall violation, and (5) lateral wall violation. Each condition was examined utilizing fluoroscopy with posteroanterior, inlet, outlet, lateral, iliac oblique, and obturator oblique Judet views to simulate operative conditions. These views were obtained to evaluate critical malposition of iliac screws. We found that, for a sciatic notch violation, the obturator oblique view best demonstrated the cortical breech, while for a hip joint violation, the inlet and outlet views were best. For a medial wall violation, the iliac oblique view best showed the violation. For a lateral wall violation, we were unable to demonstrate the cortical breech using these fluoroscopic views. Fluoroscopy is an effective method to determine sciatic notch, hip joint, and medial wall violations after iliac screw placement; however, it is not effective in identifying a lateral wall violation.


Subject(s)
Bone Screws , Fluoroscopy/methods , Fracture Fixation, Internal/instrumentation , Ilium/diagnostic imaging , Ilium/surgery , Humans , Models, Biological , Reproducibility of Results , Sacroiliac Joint/diagnostic imaging , Sacroiliac Joint/surgery
7.
J Spinal Disord Tech ; 18(4): 332-6, 2005 Aug.
Article in English | MEDLINE | ID: mdl-16021014

ABSTRACT

OBJECTIVE: Segmental restoration of sagittal contour is recognized as critical for improved long-term success following instrumented lumbar fusions. As such, the use of wedged implants has become more popular. Few studies exist to assess the postoperative lordotic and disc height changes following these varied techniques in spinal fusion. An observational radiographic study examining lumbar sagittal contour and posterior intervertebral disc space height following posterior lumbar interbody fusion (PLIF) or transforaminal lumbar interbody fusion (TLIF) was conducted using vertical cages (VCs), wedged structural allograft (WSA), and threaded cylindrical cages (TCCs). METHODS: Forty-nine consecutive patients (59 spinal segments) were evaluated following single- or two-level interbody fusion with either stand-alone TCCs (n = 18 levels), WSA with posterior transpedicular compression instrumentation (n = 25 levels), or VCs with posterior transpedicular compression instrumentation (n = 16 levels). Standing lumbar radiographs were measured by two independent observers preoperatively, immediately postoperatively (within 1 week), at 6-week follow-up (range 4-8 weeks), and postoperatively (at 1-year follow-up) for segmental lordosis at each level undergoing posterior interbody arthrodesis and posterior intervertebral disc space height to assess indirect nerve root decompression. RESULTS: At the 1-year follow-up, postoperative lordosis was improved in the VC group (+5.3 degrees ; P < 0.005), whereas it decreased in the WSA group (-0.9 degrees ; P = 0.407) and TCC group (-3.5 degrees ; P < 0.005). The posterior disc space height decreased in the VC group (-0.5 mm; P = 0.109), whereas it increased for both the WSA group (+1.2 mm; P = 0.05) and the TCC group (+0.8 mm; P = 0.219). CONCLUSIONS: PLIF with stand-alone TCC and PLIF (or TLIF) with WSA and posterior transpedicular instrumentation results in an increased posterior disc height and thus improved indirect nerve root decompression. PLIF (or TLIF) with VC and posterior transpedicular instrumentation results in an overall decrease in posterior disc height. However, TCC and WSA resulted in a loss of lumbar lordosis, whereas VC resulted in an increase in lumbar lordosis.


Subject(s)
Bone Transplantation , Internal Fixators , Intervertebral Disc/diagnostic imaging , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Spinal Fusion/methods , Spine/diagnostic imaging , Adult , Bone Transplantation/adverse effects , Equipment Design , Female , Humans , Internal Fixators/adverse effects , Lordosis/diagnostic imaging , Male , Middle Aged , Postoperative Period , Radiography , Spinal Fusion/adverse effects , Spinal Fusion/instrumentation , Transplantation, Homologous
8.
Spine (Phila Pa 1976) ; 29(1): 63-9, 2004 Jan 01.
Article in English | MEDLINE | ID: mdl-14699278

ABSTRACT

STUDY DESIGN: A computer-aided design analysis. OBJECTIVES: To introduce the concept of volumetric spinal canal intrusion and report the relative intrusion volumes for thoracic pedicle screws compared to thoracic laminar and pedicle hooks. SUMMARY OF BACKGROUND DATA: Thoracic pedicle screws are being used more frequently; however, there is concern about neurologic risk from medial misplacement. The accepted alternative to screws is hooks. Laminar and pedicle hooks also have significant obligatory spinal canal intrusion. To date, there have been no comparison studies. METHODS: Volumetric analysis of canal intrusion of pedicle screws and hooks was performed by computer-aided design CAM. All implants were of a single product line by a single manufacturer (CD Horizon M8, Medtronic Sofamor Danek). Intrusion of pedicle screws with medial positioning was analyzed in 0.5-mm increments, including a calculation of the "screw shadow," representing additional space not available for the spinal cord between screw threads and lateral to a medially positioned screw with intrusion greater than the screw radius. The length of screw intrusion was determined from postoperative CT scans in patients with thoracic pedicle screw instrumentation. All hook styles were analyzed. The volume of the footplate in line with the dorsal surface of the footplate was considered the intruding volume for laminar hooks, with increasing offset in 0.25-mm increments to represent imperfect fit. Half of the volume of the footplate was considered to be the intruding volume for pedicle hooks since a properly positioned pedicle hook straddles the pedicle. RESULTS: Volumetric intrusion for a 4.5-mm screw ranged from 2.2 mm3 (0.5 mm medial perforation) to 83.4 mm3 (3.0 mm perforation). For a 5.5-mm screw, intrusion volume range was from 1.3 mm3 to 83.2 mm3. Accounting for the "screw shadow," the volumetric intrusion was 9.83 mm3 to 116.3 mm3 and 10.88 mm3 to 134.89 mm3, respectively. Hook volumetric intrusion ranged from 21.15 mm3 for a pediatric narrow-blade ramped pedicle hook to 113.9 mm3 for a wide-blade laminar hook with 1.0 mm of step-off. CONCLUSIONS: A 4.5-mm or 5.5-mm thoracic pedicle screw must have a medial perforation of >or=1.5 mm to have the same volumetric spinal canal intrusion as a pediatric narrow-blade pedicle hook, the smallest hook footplate. Further, the medial violation must be >3 mm to approach the same volumetric intrusion as the largest hook. Accounting for the "screw shadow," a thoracic pedicle screw must have a medial perforation of >2 mm to approach the same intrusion volume as a standard pedicle hook. In the absence of direct neural injury, this explains the clinical finding of medial perforation of up to 4 mm without neurologic compromise.


Subject(s)
Bone Screws/standards , Orthopedic Fixation Devices/standards , Orthopedic Procedures/instrumentation , Spinal Canal/surgery , Animals , Humans , Materials Testing/methods , Radiography , Software , Spinal Canal/diagnostic imaging , Thoracic Vertebrae
9.
Spine J ; 3(3): 213-9, 2003.
Article in English | MEDLINE | ID: mdl-14589202

ABSTRACT

BACKGROUND CONTEXT: Many studies have reported on the use of anterior instrumentation for thoracolumbar scoliosis and more recently thoracic scoliosis. However, the optimal construct design remains an issue of debate. PURPOSE: To optimize construct design and enhance implant survival until a successful spinal arthrodesis is achieved. STUDY DESIGN: This study evaluated the effect of rod diameter and intervertebral cages on construct stiffness and rod strain using a long-segment, anterior thoracic scoliosis model with varying levels of intervertebral reconstruction. METHODS: Sixteen fresh-frozen calf spine specimens (T1 to L1) were divided into two groups based on rod diameter reconstruction (4 mm and 5 mm). Testing included axial compression, anterior flexion, extension and lateral bending with variations in the number and level of intervertebral cage reconstructions: apical disc (one), end discs (two), apical and end discs (three), all seven levels (seven). Multisegmental construct stiffness and rod strain were determined and normalized to the intact specimen for analysis. RESULTS: The seven-level intervertebral cage construct showed significantly greater stiffness in axial compression for both the 4-mm (366% increased stiffness) and 5-mm (607% increased stiffness) rod groups (p<.001). The remaining constructs were not significantly different from each other (p>.05). In flexion, similar results were obtained for the 4-mm construct (p<.001) but not the 5-mm construct, because the reconstruction-alone, one-, two- and three-cage constructs were all significantly stiffer than the intact specimen (p<.05). Multisegmental construct stiffness under extension loading, as well as right and left lateral bending, also exhibited significant differences between the seven-level interbody cage reconstructions and the remaining constructs. Apical rod strain for both the 4-mm-rod and 5-mm-rod groups were significantly higher for the two cage constructs (a cage at either end but not the apex where the strain gauges were located) as compared with the other constructs (p<.05). These differences were more pronounced in the 4-mm-rod group. Similar results were obtained in anterior flexion, extension and lateral bending. CONCLUSIONS: Intervertebral cages at every level significantly improved construct stiffness compared with increasing rod diameter alone. Moreover, cages markedly decreased rod strain, and when structural interbody supports were not used, axial compression created the greatest rod strain.


Subject(s)
Bone Nails , Internal Fixators , Scoliosis/surgery , Spinal Fusion , Animals , Biomechanical Phenomena , Cattle , Equipment Design , Materials Testing , Pliability , Weight-Bearing
10.
J Bone Joint Surg Am ; 85(1): 115-21, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12533581

ABSTRACT

BACKGROUND: This biomechanical study was designed to evaluate the predictive ability of dual-energy x-ray absorptiometry, cortical bone geometry as determined with computed tomography, and radiography in the assessment of torsional load to failure in femora with and without notching. METHODS: Thirteen matched pairs of cadaveric femora were randomized into two groups: a notched group, which consisted of femora with a 3-mm anterior cortical defect, and an unnotched group of controls. Each pair then underwent torsional load to failure. The ability of a number of measures to predict femoral torsional load to failure was assessed with use of regression analysis. These measures included dual-energy x-ray absorptiometry scans of the proximal and the distal part of the femur, geometric measures of both anterior and posterior cortical thickness as well as the polar moment of inertia of the distal part of the femur as calculated on computed tomography scans, and the Singh osteoporosis index as determined on radiographs. RESULTS: The torsional load to failure averaged 98.9 N-m for the notched femora and 143.9 N-m for the controls; the difference was significant (p < 0.01). Although several variables correlated with torsional load to failure, distal femoral bone-mineral density demonstrated the highest significant correlation (r = 0.85; p < 0.001). Moreover, multiple regression analysis showed that a combination of distal femoral bone-mineral density and polar moment of inertia calculated with the posterior cortical thickness (adjusted r (2) = 0.79; p < 0.001) had the strongest prediction of torsional load to failure in the notched group. The addition of other measures of cortical bone geometry, proximal femoral bone-mineral density, or radiographic evidence of osteopenia did not significantly increase the model's predictive ability. CONCLUSIONS: Femoral notching significantly decreases distal femoral torsional load to failure and is best predicted by a combination of the measures of distal femoral bone-mineral density and polar moment of inertia. Together, these values account for the amount of bone mass present and the stability provided by the cortical shell architecture.


Subject(s)
Absorptiometry, Photon , Femoral Fractures/diagnostic imaging , Femoral Fractures/physiopathology , Femur/diagnostic imaging , Femur/physiopathology , Osteoporosis/diagnostic imaging , Osteoporosis/physiopathology , Torsion Abnormality/diagnostic imaging , Torsion Abnormality/physiopathology , Weight-Bearing/physiology , Aged , Aged, 80 and over , Bone Density/physiology , Female , Femoral Fractures/surgery , Femur/surgery , Humans , Male , Middle Aged , Osteoporosis/surgery , Predictive Value of Tests , Prosthesis Implantation , Tomography, X-Ray Computed
11.
Am J Sports Med ; 30(5): 684-8, 2002.
Article in English | MEDLINE | ID: mdl-12239002

ABSTRACT

BACKGROUND: In an effort to improve the strength and stiffness of anterior cruciate ligament grafts, several authors have advocated alterations of graft structure and orientation, including braiding the tendons in hamstring tendon grafts. HYPOTHESIS: Braiding hamstring tendons does not increase graft strength and stiffness. STUDY DESIGN: Controlled laboratory study. METHODS: Sixteen hamstring tendon and 21 bone-patellar tendon-bone grafts were harvested from 12 cadavers and divided into three groups: 1) braided four-strand hamstring tendon, 2) unbraided four-strand hamstring tendon, and 3) bone-patellar tendon-bone. All grafts were placed under a 50-N preload on a servohydraulic testing device and were tensioned to failure. RESULTS: The strength and stiffness of the tested specimens averaged 427 +/- 36 N and 76 +/- 10 N/mm, respectively, for braided specimens, 532 +/- 44 N and 139 +/- 18 N/mm for unbraided specimens, and 574 +/- 46 N and 158 +/- 15 N/mm for patellar tendon specimens. There was a 20% decrement in hamstring tendon graft tensile strength and a 45% decrease in stiffness after braiding because of the suboptimal multidirectional orientation of individual tendons within the braided grafts. CONCLUSIONS: In vitro braided hamstring tendon grafts demonstrated mechanically inferior strength and stiffness characteristics compared with unbraided hamstring tendon grafts and patellar tendon grafts. CLINICAL RELEVANCE: Braiding of hamstring tendon grafts provides no mechanical advantage in anterior cruciate ligament reconstruction.


Subject(s)
Anterior Cruciate Ligament/surgery , Knee Joint/surgery , Tendons/transplantation , Aged , Aged, 80 and over , Biomechanical Phenomena , Cadaver , Female , Humans , Male , Statistics, Nonparametric , Thigh
12.
Spine (Phila Pa 1976) ; 27(14): 1558-66, 2002 Jul 15.
Article in English | MEDLINE | ID: mdl-12131718

ABSTRACT

STUDY DESIGN: This retrospective observational study evaluated 399 transpedicular thoracic screws using postoperative computed tomography (CT). OBJECTIVES: To examine the in vivo accuracy of transpedicular thoracic screws in patients with and without coronal plane spinal deformities. SUMMARY OF BACKGROUND DATA: There are no comparative studies regarding the safety and accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. METHODS: Curve magnitude and segmental vertebral rotation were determined from preoperative radiographs. Postoperative CT was used to assess the placement accuracy of titanium thoracic pedicle screws. RESULTS: Forty-seven patients underwent instrumented posterior spinal fusion using 399 titanium thoracic pedicle screws. Fully contained screw accuracy in patients with coronal plane spinal deformities was less than in patients without coronal plane spinal deformities at T9-T12 (59% vs. 73%, P = 0.04) and overall (42% vs. 62%, P = 0.001). There was no difference between the overall percentages of acceptably positioned screws (< or = 2 mm of medial or < or = 6 mm of lateral pedicle perforation) in patients with coronal plane spinal deformities (98%) versus patients without coronal plane spinal deformities (99%) (P = 0.69). Penetration of the anterior vertebral cortex was more frequent in patients with coronal plane spinal deformities than in those without coronal plane spinal deformities (8.0% vs. 1.0%, P = 0.008). There was no correlation between the accuracy of screw placement and the degree of segmental rotation, screw proximity to the curve apex, or screw position relative to the curve concavity or convexity (P > 0.12). There were no neurologic or vascular complications. CONCLUSIONS: The overall percentage of acceptably positioned screws was 98% in patients with coronal plane spinal deformities and 99% in patients without coronal plane spinal deformities. In patients with coronal plane spinal deformities, penetration of the pedicle wall and the anterior vertebral cortex was increased at T9-T12 and overall.


Subject(s)
Bone Screws , Spinal Fusion/instrumentation , Spine/abnormalities , Thoracic Vertebrae/surgery , Adolescent , Adult , Child , Female , Humans , Male , Middle Aged , Reproducibility of Results , Spinal Fusion/methods , Thoracic Vertebrae/diagnostic imaging , Tomography, X-Ray Computed
13.
Foot Ankle Int ; 23(2): 102-6, 2002 Feb.
Article in English | MEDLINE | ID: mdl-11858328

ABSTRACT

The effects of tibial malrotation on the biomechanics of the tibiotalar joint were studied using a cadaveric model loaded in an Instron 8521 materials testing device and a TEKScan I-Scan thin-film resistive ink pressure measuring system. Testing of 23 legs was performed using rotational conditions of 10 and 20 degrees internal and external rotation as well as neutral rotation. All rotational conditions were found to decrease joint contact area. Peak pressures were significantly greater with 20 degrees internal rotation as well as 20 degrees external rotation. Total load across the joint was significantly lower for both 10 and 20 degrees of external rotation. In conclusion, rotational deformity across the tibiotalar joint results in significant alteration of overall joint biomechanics and should be minimized whenever possible.


Subject(s)
Ankle Joint/physiology , Biomechanical Phenomena , Bone Malalignment/physiopathology , Range of Motion, Articular/physiology , Talus/physiology , Tibia/physiopathology , Cadaver , Humans , Pressure , Probability , Sensitivity and Specificity , Stress, Mechanical , Weight-Bearing
14.
Spine (Phila Pa 1976) ; 27(1): E15-7, 2002 Jan 01.
Article in English | MEDLINE | ID: mdl-11805653

ABSTRACT

STUDY DESIGN: A case involving microradiographic and histopathologic analysis of an explanted human corpectomy mesh cage is reported. OBJECTIVE: To describe the clinical circumstance, the radiographic appearance, and the histopathologic assessment of a titanium mesh device explanted from a two-level corpectomy. SUMMARY OF BACKGROUND DATA: To the authors' knowledge, no published microradiographic or histopathologic reports have described a retrieved human corpectomy cage. METHODS: The explanted device was stained using Osteochrome Villanueva bone stain and underwent routine decalcified histologic processing and embedding in polymethylmethacrylate. Midsagittal sections were prepared and polished to 100 microm for histologic and microradiographic analysis. RESULTS: Microscopic analysis demonstrated normal-appearing lamellar and woven trabecular bone in close contact with the titanium implant interface. Further analysis of serial sections indicated that, on the average, 35% (range, 30-40%) of the inner device region contained trabecular bone. CONCLUSION: Osteosynthesis and bone remodeling can occur within titanium corpectomy cages. METHODS: This study involved one titanium mesh device (Harms cage), 20 mm in diameter and 45 mm long, explanted from a two-level corpectomy clinical case. This device was retrieved, processed, and analyzed after informed patient consent and approval from the authors' institutional review board.


Subject(s)
Empyema/complications , Postoperative Complications/etiology , Prostheses and Implants , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/pathology , Spinal Fusion/adverse effects , Adult , Empyema/pathology , Empyema/surgery , Female , Humans , Humerus/transplantation , Kyphosis/diagnosis , Kyphosis/etiology , Kyphosis/surgery , Osteomyelitis/complications , Osteomyelitis/diagnosis , Osteomyelitis/surgery , Postoperative Complications/surgery , Prostheses and Implants/adverse effects , Prosthesis-Related Infections/surgery , Plastic Surgery Procedures , Reoperation , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL
...